Download PDF Datasheet | Package Size
1×2 980/1064nm Fused PM Fiber Standard WDM
Features
  • Low Excess Loss
  • High Extinction Ratio
  • High Power Handling
  • Available for Slow or Fast Axis Operation
  • Telcodia GR-1221 Compliant Test
Applications
  • PM Fiber EDFAs
  • Monitoring in Coherent Systems
  • Fiber Lasers
Specifications
Parameter Unit Premium A Grade
Pump Channel nm 980±5
Insertion Loss Max dB 0.5 0.7
Polarization Extinction Ratio Min dB 17 15
Isolation@1064±5nm Min dB 13 11
Signal Channel nm 1064±5
Insertion Loss Max dB 0.5 0.7
Polarization Extinction Ratio Min dB 17 15
Isolation@980±5nm Min dB 13 11
Operating Power Max W 2
Operating Temperature °C -40 to +85
Storage Temperature °C -50 to +85
Package Type mm S9 / S10 / M3
Typical Spectrum
Ordering Information
P
M
S
W
0
0

Wavelength

C=980/1064nm
S=Specify

Structure

1=1×2

Grade

P=Premium
A=A Grade

Package

8=S9 with 250μm bare fiber pigtail
9=S10 with 900μm loose tube
F=M3 with 3mm cable

Fiber Type

E=Panda fiber

Fiber Length

0=0.5m
1=0.75m
2=1.0m
S=Specify

Connector

0=None
1=FC/PC
2=FC/SPC
3=FC/APC
7=FC/UPC